Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1551411

RESUMO

Objective: The aim of the study was to report the aplicability of intraoral scanning while rubber dam isolation is in place. Material and Methods: Female patient, 50 years old, required restorative procedures on teeth 35 and 37. An intraoral scan was initially performed on both arches. Isolation was carried out from 33 to 37, tooth preparation and immediate dentin sealing were carried out. A new scan with the rubber dam in place was performed and a CAD/CAM lithium disilicate hybrid block was digitally designed, milled, crystallized and cemented under the tooth surface with the rubber dam still in position. After completing this stage, the rubber dam was removed, the occlusion was verified, presenting excellent aesthetic and functional results. Results: The absolute isolation process used in the present study works as an excellent device for gingival retraction. Conclusion: The absolute isolation can be recommended in clinical activities of intraoral scanning favoring the quality of the final result of treatments (AU)


Objetivo: O objetivo do estudo foi relatar a aplicabilidade do escaneamento intraoral sob isolamento absoluto. Material e Métodos: Paciente do sexo feminino, 50 anos, necessitou de procedimentos restauradores nos dentes 35 e 37. Uma varredura intraoral foi inicialmente realizada em ambos os arcos. O isolamento absoluto foi feito de 33 a 37, permitindo a realização do preparo dentário e selamento imediato da dentina. Um novo escaneamento com o dique de borracha colocado foi realizado e um bloco híbrido de dissilicato de lítio CAD/CAM foi projetado digitalmente, fresado, cristalizado e cimentado sob a superfície dentária ainda com o dique de borracha em posição. Após a finalização dessa etapa, o dique de borracha foi removido, a oclusão foi verificada apresentando ótimos resultados estéticos e funcionais. Resultados: O isolamento absoluto utilizado no presente estudo funciona como um excelente dispositivo para retração gengival. Conclusão: O isolamento absoluto pode ser recomendado em atividades clínicas de escaneamento intraoral favorecendo a qualidade do resultado final dos tratamentos (AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Diques de Borracha , Desenho Assistido por Computador , Encaixe de Precisão de Dentadura , Tecnologia Digital , Reabilitação Bucal
2.
RGO (Porto Alegre) ; 71: e20230055, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1521438

RESUMO

ABSTRACT Objective: The present study analyzed the biomechanical behavior of the generated stress on the external surface of the rehabilitation elements (implants, components and infrastructures) according to different occlusion patterns on a fixed partial denture on osseointegrated implants. Method: The experimental groups varied according to the location of the occlusal load applied to the Fixed partial denture, with a total occlusal load of 750N in all groups, opting for greater loads on the occlusal table of the molar in relation to the premolar. This evaluation was performed by the finite element method with simulations by the AnsysWorkbench 16.0 Software program. Results: The results analyzed for implants and their components showed that the more posterior the occlusal loading, the greater the stress developed (group 4), always in the connection area between the prosthetic component and the implant, as this location can induce greater screw loosening. The results analyzed for the infrastructures showed that the most distributed occlusal loading possible (group 1) is the best situation for generating less stress. However, even in group 3 which obtained the highest stresses in the critical area of the prosthetic connection, the zirconia flexural strength values generated were not worrisome. Conclusion: It can be concluded that the occlusal adjustment of Fixed partial dentures are preponderant and decisive factors for correct biomechanics and preservation of the system in the long term in order to avoid possible damage and/or failures, and exert significant and notorious differences in the behavior of all structures studied herein.


RESUMO Objetivo: O presente estudo analisou o comportamento biomecânico do estresse gerado na superfície externa dos elementos reabilitadores (implantes, componentes e infraestruturas) de acordo com diferentes padrões de oclusão em uma prótese parcial fixa sobre implantes osseointegrados. Métodos: Os grupos experimentais variaram de acordo com a localização da carga oclusal aplicada na Prótese Parcial Fixa, com carga oclusal total de 750N em todos os grupos, optando por cargas maiores na mesa oclusal do molar em relação ao pré-molar. Esta avaliação foi realizada pelo método dos elementos finitos com simulações pelo programa AnsysWorkbench 16.0 Software. Resultados: Os resultados analisados para os implantes e seus componentes mostraram que quanto mais posterior a carga oclusal, maior a tensão desenvolvida (grupo 4), sempre na área de conexão entre o componente protético e o implante, pois este local pode induzir maior soltura do parafuso. Os resultados analisados para as infraestruturas mostraram que a carga oclusal mais distribuída possível (grupo 1) é a melhor situação para gerar menos estresse. No entanto, mesmo no grupo 3 que obteve as maiores tensões na área crítica da conexão protética, os valores de resistência à flexão da zircônia gerados não foram preocupantes. Conclusões: Pode-se concluir que o ajuste oclusal das Próteses Parciais Fixas são fatores preponderantes e decisivos para correta biomecânica e preservação do sistema a longo prazo a fim de evitar possíveis danos e/ou falhas, e exercem diferenças significativas e notórias no comportamento de todas as estruturas aqui estudadas.

3.
Braz. dent. sci ; 24(2): 1-9, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1177588

RESUMO

Objective: The purpose of the present study was to synthesize and characterize lithium disilicate glass-ceramics through the Li2O-SiO2system for determining the most satisfactory sintering parameter by evaluating the crystalline composition, microstructure and mechanical properties. Material and methods: The glass-ceramics were prepared from a glass precursor by means of the melting/cooling technique with a composition of 33.33 Li2O and 66.67 SiO2 (mol.%). The specimens were compressed by the uniaxial pressing technique and three different thermal treatments were used for sintering: 850 °C (Group 1), 900 °C (Group 2), and 950 °C (Group 3), which were determined based on the differential scanning calorimetry (DSC) result. The glass-ceramics were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Archimedes method, microhardness and biaxial flexural strength analyses. Results: The results regarding XRD predominantly showed lithium disilicate phase for all the heat treatments performed. Moreover, grains with a needle form were more predominantly observed in the SEM images for Group 3, as well as a higher densification and consequently higher mechanical properties. In contrast, Group 1 presented the lowest mechanical properties and densification, as well as the highest porosity. Conclusion: The present study demonstrated how extremely important it is to follow the heat treatment recommended by the manufacturers of ceramics, including time and temperature, which possess direct effects in the crystalline phase formation, as well as in the material's microstructure and mechanical properties (AU)


Objetivo: O presente estudo teve como objetivo sintetizar e caracterizar uma vitrocerâmica de dissilicato de lítio através do sistema Li2O-SiO2para determinar o parâmetro de sinterização mais satisfatório através da avaliação da composição cristalina, microestrutura e propriedades mecânicas. Material e Métodos: As vitrocerâmicas foram preparadas a partir de um vidro precursor pelo método fusão/resfriamento utilizando a composição de 33.33 Li2O e 66.67 SiO2 (mol.%). As amostras foram prensadas utilizando uma técnica de prensagem uniaxial e três tratamentos térmicos diferentes foram utilizadas para sinterização: 850 °C (Grupo 1), 900 °C (Grupo 2), e 950 °C (Grupo 3), que foram determinados através do resultado da análise diferencial de calorimetria. As vitrocerâmicas foram caracterizadas através das análises de difração de raios X (DRX), microscopia eletrônica de varredura (MEV), métodos de Arquimedes, microdureza e ensaio de flexão biaxial. Resultados: Os resultados de DRX mostraram predominantemente a fase de dissilicato de lítio para todos os tratamentos realizados. Além disso, grãos com forma agulhada foram mais predominantemente observados por MEV no grupo 3, assim como uma densificação maior e consequentemente valores maiores das propriedades mecânicas. Em contraste, o grupo 1 apresentou os menores valores de propriedades mecânicas e densificação, e também a maior porosidade. Conclusão: O presente estudo demonstrou como é extremamente importante seguir o tratamento térmico recomendado pelos fabricantes de cerâmica, incluindo tempo e temperatura, que possuem efeitos diretos na formação da fase cristalina, assim como na microestrutura do material e propriedades mecânicas. (AU)


Assuntos
Difração de Raios X , Microscopia Eletrônica de Varredura , Cristalização
4.
Braz. dent. sci ; 24(2): 1-7, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1177576

RESUMO

Purpose: To evaluate the effect of fibromucosa height on the stress distribution and displacement of mandibular total prostheses during posterior unilateral load, posterior bilateral load and anterior guidance using the finite element analysis (FEA). Material and methods: 3D virtual models were made to simulate the stress generated during different mandibular movements in a total prosthesis. The contacts were simulated according to the physiology, being considered perfectly bonded between cortical and medullar bones; and between cortical bone and mucosa. Non-linear frictional contact was used for the total prosthesis base and fibromucosa, allowing the prosthesis to slide over the tissue. The cortical bone base was fixed and the 100 N load was applied as unilateral load, posterior bilateral load and anterior guidance simulation. The required results were for maximum principal stress (MPa), microstrain (mm/mm) and total displacement (mm). The numerical results were converted into colorimetric maps and arranged according to corresponding scales. Results: The stress generated in all situations was directly proportional to the fibromucosa height. The maximum principal stress results demonstrated greater magnitude for anterior guidance, posterior unilateral and posterior bilateral, respectively. Only posterior unilateral load demonstrated an increase in bone microstrain, regardless of the fibromucosa height. Prosthesis displacement was lower under posterior bilateral loading. Conclusion: Posterior bilateral loading is indicated for total prosthesis because it allows lower prosthesis displacement, lower stress concentration at the base of the prosthesis and less bone microstrain. (AU)


Objetivo: Avaliar o efeito da altura da fibromucosa na distribuição de tensões e deslocamento das próteses totais mandibulares durante a carga unilateral posterior, carga bilateral posterior e orientação anterior usando a análise por elementos finitos (FEA). Material e métodos: Modelos virtuais 3D foram confeccionados para simular a tensão gerada durante diferentes movimentos mandibulares em uma prótese total. Os contatos foram simulados de acordo com a fisiologia, sendo considerados perfeitamente unidos entre os ossos corticais e medulares; e entre o osso cortical e a mucosa. O contato friccional não linear foi utilizado entre a base total da prótese e a fibromucosa, permitindo que a prótese deslizasse sobre o tecido. A base do osso cortical foi fixada e a carga de 100 N aplicada como carga unilateral, carga bilateral posterior e simulação de guia incisiva anterior. Os resultados foram calculados em tensão máxima principal (MPa), microdeformação (mm/mm) e deslocamento total (mm). Os resultados numéricos foram convertidos em mapas colorimétricos e organizados de acordo com as escalas correspondentes. Resultados: A tensão gerada em todas as situações foi diretamente proporcional à altura da fibromucosa. Os resultados de tensão máxima principal demonstraram maior magnitude durante a carga anterior, posterior unilateral e posterior bilateral, respectivamente. Apenas a carga unilateral posterior demonstrou aumento da microdeformação óssea, independente da altura da fibromucosa. O deslocamento da prótese foi menor sob carga bilateral posterior. Conclusão: A carga bilateral posterior é indicada para prótese total, pois permite menor deslocamento da prótese, menor concentração de tensões na base da prótese e menor microdeformação óssea (AU)


Assuntos
Análise de Elementos Finitos , Oclusão Dentária , Prótese Total
5.
Braz. dent. sci ; 24(2): 1-5, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1177573

RESUMO

Objetives: this study aimed to fabricate electrospun-based polyetherimide (PEI) fibers, under controlled parameters, and to perform a diameter analysis for potential mechanical improvement of dental materials. Material and Methods: PEI pallets (0.75 g) were dissolved in 2 mL of chloroform and then processed by electrospinning, under a flow rate of 1mLh-1, three different electrical voltages (10kV, 15kV and 20kV) and three distances (10 cm, 15 cm and 18 cm) between the needle tip and collector. These parameter combinations resulted in nine experimental groups that were analyzed using scanning electron microscopy (SEM) and image processing program for diameter measurement. Statistical analysis was performed using two-way ANOVA with post-hoc Tukey (5% significance). Results: from SEM images it was possible to observe formation of solid, misaligned and flawless defect-free fibers. And from the statistical analysis, distance (p = 0,0026) and the electric tension (p = 0,0012) showed a significant difference, but not for interaction between then (p = 0,4486). Conclusion: thus, it can be concluded that there is a possibility of the morphology control of PEI electrospun fibers, such as diameter, that can be used for a variety of applications such as incorporation in dental materials in order to improve its properties. (AU)


Objetivos: o objetivo deste estudo foi fabricar fibras de polieterimida à base de eletrofiação (PEI), sob parâmetros controlados, e realizar uma análise de diâmetro para potencial aprimoramento mecânico de materiais odontológicos. Material e métodos: paletes de PEI (0,75 g) foram dissolvidos em 2 mL de clorofórmio e processados pela eletrofiação, sob uma razão de fluxo de 1 mLh-1, três tensões elétricas diferentes (10 kV, 15 kV e 20 kV) e três distâncias (10 cm, 15 cm e 18 cm) entre a ponta da agulha e o coletor. Essas combinações de parâmetros resultaram em nove grupos diferentes que foram analisadas usando microscopia eletrônica de varredura (MEV) e programa de processamento de imagem para medição de diâmetro. Resultados: a partir das imagens de MEV foi possível observar a formação de fibras sólidas, desalinhadas e sem defeitos. E a partir da análise estatística, a distância (p = 0,0026) e a tensão elétrica (p = 0,0012) apresentaram diferença significativa, mas não para interação entre elas (p = 0,4486). Conclusão: assim, pode-se concluir que existe a possibilidade de controle da morfologia das fibras eletrofiadas PEI, como o diâmetro, que pode ser utilizado para uma variedade de aplicações, como incorporação em materiais dentários, a fim de melhorar suas propriedades (AU)


Assuntos
Polímeros , Resistência à Tração , Microscopia Eletrônica de Varredura , Materiais Dentários
6.
Braz. dent. sci ; 24(3): 1-13, 2021. tab, ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1281321

RESUMO

Objective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods: 3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results:The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusion: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design. (AU).


Objetivo: Avaliar o efeito de quatro desenhos de preparo, dois materiais cerâmicos e dois tipos de contato oclusais na distribuição de tensão de laminado cerâmico em incisivo central superior. Material e métodos: Modelos 3D foram realizados em software de modelagem contendo esmalte, dentina, polpa, simulador de ligamento periodontal e uma base de resina de poliuretano. Os desenhos foram modelados e exportados para o software de engenharia para realizar análise estatística estrutural. Para a malha, foram usados um total de 155429 elementos tetraedros e 271683 nós, após teste de convergência de 10%. Dois materiais, dissilicato de lítio e cerâmica feldspática, foram simulados. Uma carga estática de 100N em 45º foi aplicada no terço incisal e médio na região palatina do dente, guiada pelo plano oclusal e a base foi restringida em todas as direções. A tensão de tração foi o critério de falha escolhido para a análise. Resultados: A análise de elementos finitos mostrou que os desenhos mais conservadores apresentaram menor concentração de tensão no laminado cerâmico. Contudo, as maiores concentrações de tensões foram observadas no laminado de dissilicato de lítio com preparo estendido no terço médio. O tipo de contato oclusal apresentou diferentes padrões de tensões entre os diferentes desenhos, o contato incisal mostrou maior concentração de tensão em relação ao contato do terço médio independentemente do material cerâmico Conclusão: Para a confecção de laminado cerâmico em incisivo central superior, a cerâmica feldspática apresentou resultados promissores e é recomendada quando for feito preparo estendido. Em relação aos tipos de contato, o contato incisal é mais sujeito a falhas independentemente da cerâmica e desenho do preparo. (AU)


Assuntos
Cerâmica , Análise de Elementos Finitos , Facetas Dentárias
7.
Braz. dent. sci ; 24(3): 1-7, 2021. tab, ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1281904

RESUMO

Objective: The aim of the study was to fabricate and morphologically characterize ultrafine Polyetherimide fibers (PEI) associated with Polymethylmethacrylate (PMMA) ­ PP (group formed by the association of PEI with PMMA), produced by the electrospinning process. Material and Methods: A solution of PEI (0.562 g) + PMMA (0.377 g) dissolved in 2.5 mL of chloroform, 0.85 mL of Dimethylformamide (DMF) and 0.85 mL of 1.1.2.2 Tetrachloroethane (TCE) was prepared. For the electrospinning process, different continuous voltages (10 to 18 kV) and two different distances (8 and 12 cm) between the needle tip and the collecting apparatus were used, giving rise to 6 distinct groups of ultrafine fibers (PP 1 to 6) that were observed in Scanning Electron Microscopy to check for defects and calculate the average diameter of the fibers. Results: The best parameter, the parameter that was most effective for the production of fibers, observed was subjected to Energy Dispersion X-ray Spectroscopy (EDS), X-ray Diffraction (XRD) and Contact Angle Analysis tests. The data were analyzed using the ANOVA and Tukey test (p <0.05). From the comparative analysis of the pre-established parameters, the pattern of PP4 ultrafine fibers was shown to be more effective. Conclusion: The PP4 standard (13 kV ­ 12 cm) had an average diameter of 0.37 µm. An adequate parameter to electrospinning was able to produce ultrafine fibers of PMMA/PEI (AU)


Introdução: O objetivo do estudo foi sintetizar e caracterizar morfologicamente fibras ultrafinas de Polieterimida (PEI) associadas ao Polimetilmetacrilato (PMMA) - PP (grupo formado pela associação de PEI com PMMA), produzidas pelo processo de eletrofiação. Material e Métodos: Foi preparada uma solução de PEI (0,562 g) + PMMA (0,377 g) dissolvido em 2,5 mL de clorofórmio, 0,85 mL de Dimetilformamida (DMF) e 0,85 mL de 1.1.2.2 Tetracloroetano (TCE). Para o processo de eletrofiação, foram utilizadas diferentes tensões contínuas (10 a 18 kV) e duas distâncias diferentes (8 e 12 cm) entre a ponta da agulha e o aparelho coletor, dando origem a 6 grupos distintos de fibras ultrafinas (PP 1 a 6) que foram observados em Microscopia Eletrônica de Varredura para verificar defeitos e calcular o diâmetro médio das fibras. Resultados: O melhor parâmetro, o parâmetro mais eficaz para a produção de fibras, observado foi submetido aos testes de Espectroscopia de Dispersão de Energia (EDS), Difração de Raios X (DRX) e Análise do Ângulo de Contato. Os dados foram analisados pela ANOVA e teste de Tukey (p <0,05). A partir da análise comparativa dos parâmetros pré-estabelecidos, o padrão das fibras ultrafinas PP4 mostrou-se mais eficaz. Conclusão: O padrão PP4 (13 kV - 12 cm) apresentou diâmetro médio de 0,37 µm. Um parâmetro adequado para eletrofiação foi capaz de produzir fibras ultrafinas de PMMA / PEI. (AU)


Assuntos
Microscopia Eletrônica de Varredura , Polimetil Metacrilato , Espectroscopia de Perda de Energia de Elétrons
8.
Braz. dent. sci ; 23(3): 1-7, 2020. tab, ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1116244

RESUMO

Objective: This study aimed to evaluate the biomechanical behaviour of endodontically treated teeth with direct veneer that received or not intra-radicular glass fiber post by finite elements analysis. Material and methods: Six models were designed, varying the presence or absence of glass fiber post and the thickness of direct veneer (0.5, 0.7 and 1 mm). Tridimensional models of maxillary central incisors were obtained with CAD software, Rhinoceros 4.0, and transferred to CAE software, ANSYS 17.2, which a 100N load was applied in a 45° on the lingual surface to simulate functional movements. Geometry contacts were bonded, and the structures were isotropic, linear, elastics, and homogeneous. After coherence and convergence analysis of mashes, the chosen fail criterion was the maximum principal stresses. Results: For cement, glass fiber post, the stress distribution was similar independently of glass fiber post presence or veneer thickness. Models with glass fiber post had better stress distribution and lower values of maximum stress for inner dentin and veneers. Veneers with 0.5 and 1 mm had higher stress concentration areas. Conclusions: It can be concluded that glass fiber post is favorable for restored teeth with direct veneers, and very thin or very thick preparations can damage the biomechanical behavior of restorations.(AU)


Objetivo: Este estudo teve como objetivo avaliar o comportamento biomecânico de dentes tratados endodonticamente com faceta direta que receberam ou não pinos de fibra de vidro intrarradicular através de análise de elementos finitos. Material e métodos: Foram desenhados seis modelos, variando a presença ou ausência do pino de fibra de vidro e a espessura da faceta direta (0,5, 0,7 e 1 mm). Modelos tridimensionais de incisivos centrais superiores foram obtidos com o software CAD, Rhinoceros 4.0, e transferidos para o software CAE, ANSYS 17.2, cuja carga de 100N foi aplicada a 45° na superfície lingual para simular movimentos funcionais. Os contatos geométricos foram colados e as estruturas eram isotrópicas, lineares, elásticas e homogêneas. Após análise de coerência e convergência de malhas, o critério de falha escolhido foi a tensão principal máxima. Resultados: Para cimento e pino de fibra de vidro, a distribuição de tensões foi semelhante independentemente da presença do pino de fibra de vidro ou da espessura da faceta. Os modelos com pinos de fibra de vidro apresentaram melhor distribuição de tensão e menores valores de tensão máxima para dentina interna e facetas. Facetas com 0,5 e 1mm apresentaram maiores áreas de concentração de estresse. Conclusões: Pode-se concluir que o pino de fibra de vidro é favorável para dentes restaurados com facetas diretas, e preparações muito finas ou muito espessas podem prejudicar o comportamento biomecânico das restaurações.(AU)


Assuntos
Dente não Vital , Análise de Elementos Finitos , Pinos Dentários , Facetas Dentárias
9.
Braz. dent. j ; 30(5): 505-510, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039138

RESUMO

Abstract The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.


Resumo O objetivo deste estudo foi investigar o desgaste tridimensional, perda volumétrica e rugosidade após a simulação de mastigação de dois materiais vitro-cerâmicos. Discos de dissilicato de lítio (LD, Emax CAD, Ivoclar) e silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity, Vita Zhanfabrick) (n=20/g) foram confeccionados e digitalizados para obtenção de arquivos de estereolitografia (STL) de cada amostra. Todos os discos foram submetidos à simulação de mastigação com configuração deslizante (30 N, 300.000 ciclos, 6 mm e 1,7 Hz) com esteatita como antagonista. As amostras foram escaneadas novamente e a perda de volume e o defeito mais profundo foram medidos usando o arquivo sobreposto da linha de base através de um software de inspeção paramétrica digital e tridimensional (GOM Inspect, Braunschweig, Alemanha). A rugosidade superficial (Ra e Rz) foi avaliada através de rugosímetro de contato. Os resultados foram analisados por ANOVA 1-fator e teste Tukey (α=0,5%). ANOVA mostrou diferenças significantes entre os grupos. Considerando a perda de volume cerâmico, comprimento do defeito e rugosidade Rz, LD (-22,09±5,57%; 0,80±0,06 µm; 3,08±1.02 µm) apresentou valores médios superiores a ZLS (-15,67±4,51%; 0,56±0,09 µm; 1.51±0.90 µm). Todos os discos exibiram pequenos arranhões na superfície conforme a direção de deslizamento com padrões de desgaste, enquanto grandes ranhuras foram observadas nos traços de desgaste. Essas mesmas áreas podem ser identificadas em azul, sobrepondo os arquivos STL antes e depois da simulação de mastigação no software de inspeção. A redução linear gerada pelo contato deslizante mostra um gráfico com uma forma de padrão de desgaste semelhante. ZLS foi mais resistente ao desgaste do que LD, com menor perda de volume e menores defeitos superficiais.


Assuntos
Cerâmica , Mastigação , Propriedades de Superfície , Teste de Materiais , Porcelana Dentária
10.
Rev. odontol. UNESP (Online) ; 48: e20190103, 2019. tab, graf
Artigo em Português | LILACS, BBO | ID: biblio-1099185

RESUMO

Resumo Introdução As resinas de polimetilmetacrilato e as bisacrílicas são materiais amplamente utilizados para a confecção de restaurações provisórias; no entanto, ambas apresentam uma característica de exotermia durante a polimerização que deve ser investigada por causa de possíveis interferências no sucesso clínico. Objetivo Avaliar a variação de temperatura de polimerização da resina bisacrílica e de uma resina acrílica quimicamente ativada, em preparos classe V, pelo método direto. Material e método Para isso, vinte dentes incisivos inferiores bovinos foram divididos em dois grupos: RA (N=10) com dentes restaurados com resina acrílica e RB (N=10) com dentes restaurados com resina bisacrílica. As mensurações das variações térmicas foram realizadas através de termopares tipo J, ligados a um termômetro óptico, e analisadas por um computador equipado com o software específico. Os dados obtidos foram analisados e submetidos à análise de médias comparadas pelo teste de Tukey (significância de 5%). Resultado Foi possível observar que não houve diferença estatística significante entre ambos os grupos experimentais (p=0,0739), mesmo que aumento de temperatura de RA tenha apresentado média maior (0,52 °C) do que RB (0,44 °C). Conclusão Não existe diferença significativa experimental entre o calor emitido pela resina acrílica e pela resina bisacrílica durante seus processos de polimerização, não definindo a característica de escolha de uma destas para as restaurações provisórias diretas.


Abstract Introduction Polymethyl methacrylate and bis-acryl resins are materials widely used for temporary restorations, however, both have a characteristic of polymerization exotermia that should be investigated because of possible interferences in clinical success. Objective to evaluate the variation of the polymerization temperature of bis-acryl resin and a chemically activated acrylic resin in the temporary restoration by the direct method. Material and method Twenty bovine mandibular incisor teeth were divided into two groups: AR (N = 10) teeth restored with acrylic resin and BR (N = 10) teeth restored with bis-acryl resin. Measurements of thermal variations were performed using type J thermocouples, connected to an optical thermometer and analyzed by a computer equipped with specific software. The obtained data were analyzed and submitted to the analysis of means compared by Tukey test (significance of 5%). Result It was observed that there was no statistically significant difference between both experimental groups (p = 0.0739), even though AR temperature increase presented higher average (0.52ºC) than BR (0.44ºC). Conclusion There is no significant experimental difference between the heat emitted by acrylic resin and bis-acryl resin during their polymerization processes, not defining the factor that characterizes a choice of a material for temporary restorations.


Assuntos
Resinas Acrílicas , Restauração Dentária Temporária , Polimerização , Polimetil Metacrilato , Temperatura Alta
11.
Braz. dent. sci ; 22(2): 163-170, 2019. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-996318

RESUMO

Objective: This study aimed the synthesis and morphological characterization of PCL electrospun fibers containing tara extract. Material and Methods: For this, tara extract synthesis was performed by two different extraction methods: rotary evaporator and extractor soxhlet. Then, two solutions were prepared by dissolving 3g of PCL in 2mL of Acetone. The first solution used 0.4 mL tara extract obtained by RE and the second solution used 0.4 mL tara extract obtained by SE. After the solutions electrospinning, under different parameters, obtaining It was obtained the experimental groups: ChTa 1 nanofibers with RE extract, under 12 Kv; ChTa 2 nanofibers with RE extract, under 15 Kv; ChTa 3 nanofibers with ES extract, under 12Kv and ChTa 4 nanofibers with ES extract, under 15kV. Scanning electron micrographs were performed for morphological analysis. Results: Fiber formation was observed for all parameters. About the fiber diameter: ChTa 1 presented a mean of 0.82 ± 0.36µm, ChTa 2 1.232 ±0471µm, ChTa 3 1.469 ± 0.614µm and ChTa 4 1.017 ± 0.417. Also the beads formation was analyzed: ChTa 1 group presented 8 beads, ChTa 2 presented 5, ChTa 3 presented 30 and ChTa 4 presented 15 beads. Conclusion: It can be concluded that it is possible to obtain an effective synthesis of electrospun membranes of PCL and Caesalpinia spinosa extract, indicating a potential of therapeutic application for lesions such as prosthetic stomatitis. (AU)


Objetivo: Este estudo objetivou a síntese e a caracterização morfológica de fibras eletrofiadas de PCL contendo extrato de tara, caracterizando sua morfologia. Material e Métodos: Para isso, a síntese do extrato de Tara foi realizada por dois diferentes métodos de extração: Evaporador rotativo e Extrator de soxhlet. Em seguida, duas soluções foram preparadas dissolvendo 3g de PCL em 2 mL de acetona. A primeira solução utilizou 0,4 mL de extrato de Tara obtida por ER. A segunda solução utilizou 0,4 mL de extrato de Tara obtida por ES. Após as soluções serem eletrofiadas, sob diferentes parâmetros, obtiveram-se os grupos experimentais: ChTa 1 nanofibras com extrato de RE, sob 12Kv; ChTa 2 nanofibras com extrato de RE, sob 15Kv; ChTa 3 nanofibras com extrato de ES, com menos de 12Kv e nanofibras de ChTa 4 com extrato de ES, sob 15kV. Micrografias eletrônicas de varredura foram realizadas para análise morfológica. Resultados: A formação de fibras foi observada para todos os parâmetros. Quanto ao diâmetro da fibra: ChTa 1 apresentou uma média de 0,82 ± 0,36 µm, o ChTa 2 1,232 ± 0471 µm, o ChTa 3 1,469 ± 0,614 µm e o ChTa 4 1,017 ± 0,417. Também foi analisada a formação dos beads: o grupo ChTa 1 apresentou 8 beads, o ChTa 2 5, o ChTa 3 30 e o ChTa 4 15. Conclusão: Pôde-se concluir que é possível obter uma síntese efetiva de membranas eletrofiadas de extrato de PCL e Caesalpinia spinosa, indicando um potencial de aplicação terapêutica para lesões como a estomatite protética. (AU)


Assuntos
Taninos , Candidíase , Nanofibras
12.
Braz. dent. sci ; 22(1): 17-22, 2019. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-986561

RESUMO

This short report evaluated the differences in stress concentration and the load to fracture of multilayered and monolayer glass ceramic discs. Using a simulated static structural analysis, the 3D model of the samples received a load of 150 N and results in maximum principal stress were obtained. For the in vitro analysis, the samples (ø 12 mm) were submitted to a compressive test (100 kgf, 1 mm/min). The data was analyzed using one-way analysis of variance and Tukey test (α = 5%). The monolayer group showed a lower stress peak (129.24 MPa) and higher load to fracture (118.38 N) than the multilayered group with 211.04MPa and 48.34N, respectively. All samples presented catastrophic failure with its origin on the tensile surface. Therefore, the monolayer ceramic group showed superior mechanical behavior than the multilayered group. (AU)


Este relato avaliou a diferença na concentração de tensão e a carga para fratura de discos de cerâmica vítrea em multicamada e monocamada. Usando uma análise estática estrutural simulada, o modelo 3D das amostras recebeu uma carga de 150 N e resultados de tensão máxima principal foram obtidos. Para a análise in vitro, as amostras (ø 12 mm) foram submetidas a um teste de compressão (100 kgf, 1 mm / min). Os dados foram analisados por análise de variância e teste de Tukey (α = 5%). O grupo em monocamada mostrou um menor pico de tensão (129,24 MPa) e maior carga para fratura (118,38N) do que o grupo multicamada com 211,04 MPa e 48,34 N, respectivamente. Todas as amostras apresentaram falha catastrófica com sua origem na superfície de tração. Portanto, o grupo em monocamada apresentou comportamento mecânico superior ao grupo multicamadas. (AU)


Assuntos
Análise de Variância , Análise de Elementos Finitos , Restauração Dentária Permanente
13.
Braz. dent. sci ; 22(1): 70-78, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-986838

RESUMO

This work studied the synthetization and morphological characterization of Polyethylmethacrylate (PEMA) nanofibers (NFs) containing titanium dioxide (TiO2) produced by the electrospinning technique. The solution to produce the nanofibers was prepared by dissolving 2.5g PEMA in 6.75mL of 1.1.2.2- tetrachloroethane and 3.375mL of dimethylformamide (DMF), and 0.405g of TiO2 was added to the solution. The nanofiber production used different distances between the tip of the needle to the collector (10, 12 and 15 cm) and two flow rates (0.05 mLh-1 and 0.08 mLh-1) were employed, while the applied voltage was 17kV. The NF morphology was analyzed by Scanning Electron Microscopy (SEM) and Image J software. We used Fourier Infrared Spectroscopy (FTIR) and Energy Dispersive X-Ray Spectroscopy (EDS) to evaluate the structural properties. All parameters were effective in the NF production, however it was shown that the distance of 12 cm produced the best NFs. The mean diameters showed no statistically significant difference between the samples. The FTIR analysis showed characteristic peaks of PEMA and TiO2 . It was concluded that the employed method was efficient for NF production containing PEMA and TiO2 , and the morphological characteristics of the NFs were influenced by the voltage and distance. (AU)


O presente trabalho estudou a sintetização e a caracterização morfologica de nanofibras (NFs) de polietilmetacrilato (PEMA) contendo dióxido de titânio (TiO2) produzidas pela técnica da eletrofiação. A solução para o preparo das nanofibras utilizou 2,5 g de PEMA dissolvidos em 6,75 mL de 1,1,2,2 - tetracloroetano (TCE) e 3,337 mL de dimetilformamida (DMF), em sequência foi adicionado 0, 405g de TiO2 à solução. Para eletrofiação, o equipamento foi constituído por uma fonte de alta tensão, uma seringa plástica com agulha de ponta reta e as NFs obtidas foram coletadas em anteparo metálico a 10, 12 e 15 cm de distância da ponta da agulha. A tensão aplicada foi de 17 kV e o fluxo de ejecção variou de 0.05 mLh-1 e 0.08 mLh1. O diâmetro e a morfologia das NFs foram avaliados por meio de Microscopia Eletrônica de Varredura (MEV) e pelo software Image J. A Espectroscopia por Transformada de Fourier (FTIR) e a Spectroscopia por energia dispersiva de raios X (EDS) avaliaram as propriedades estruturais. A análise morfológica das micrografias mostrou que a distância de 12cm da ponta da agulha até o coletor produziu as melhores NFs. O FTIR demonstrou picos característicos de PEMA e TiO2 . Diante dos resultados obtidos podemos concluir que o método empregado foi eficiente para a produção de NFs contendo PEMA e TiO2 e a variação da tensão e distancia influenciaram na morfologias das NFs.(AU)


Assuntos
Polímeros , Microscopia Eletrônica de Varredura , Eletroquímica , Nanofibras
14.
Braz. dent. sci ; 22(4): 483-487, 2019. tab
Artigo em Inglês | BBO, LILACS | ID: biblio-1024436

RESUMO

Objective: This study aimed to evaluate and compare the retention force of individual clasps made from polyamide, acetate resin and cobalt-chrome for removable partial dentures. Material and methods: Three groups of clasps were fabricated: Cr-Co ­ 10 conventional chrome-cobalt metal clasps; Ac ­ 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in acetate resin; and Poly - 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in polyamide resin. Through the tensile test, in a universal testing machine, the initial retention force of the specimens was obtained and then clasps were cycled 7200 times, immersed in artificial saliva (60 months of simulated clinical use). After cycling, tensile test was performed. Results: All groups presented a retention decrease after the cycling. Ac presented a large reduction in retentive force (61.43%), followed by Cr-Co (26.5%) and Poly (12.09%). Conclusions: Aesthetic clasps of polyamide can be used in clinical cases where the anterior supporting teeth will not be essential for good retention of the removable partial denture because this clasp showed to be more resistant than the acetate resin. (AU)


Objetivo: Este estudo teve como objetivo avaliar e comparar a força de retenção de grampos individuais feitos de poliamida, resina de acetato e cromo-cobalto para próteses parciais removíveis. Material e Métodos: Três grupos de grampos foram fabricados: Cr-Co ­ 10 grampos metálicos convencionais de cromo-cobalto; Ac - 10 grampos com apoios e braço de oposição em cromocobalto e braços de retenção em resina de acetato; e Poly - 10 grampos com apoios e braço de oposição em cromo cobalto e braço de retenção em resina de poliamida. Por meio do teste de tração, em uma máquina de ensaio universal, a força de retenção inicial dos espécimes foi obtida e então, os grampos foram ciclados 7200 vezes, imersos em saliva artificial (60 meses de uso clínico simulado). Após a ciclagem, o teste de tração foi realizado. Resultados: Todos os grupos apresentaram diminuição da retenção após a ciclagem. Ac apresentou uma grande redução na força retentiva (61,43%), seguida por Cr-Co (26,5%) e Poly (12,09%). Conclusões: Grampos estéticos de poliamida podem ser usados em casos clínicos em que os dentes de suporte anteriores não serão essenciais para uma boa retenção da prótese parcial removível, pois esse grampo mostrouse mais resistente que os de resina de acetato (AU)


Assuntos
Grampos Dentários , Materiais Dentários , Prótese Parcial Removível
15.
Rev. odontol. UNESP (Online) ; 47(4): 237-243, jul.-ago. 2018. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-961522

RESUMO

Introduction: Implant inclinations can be corrected using mini abutments at different angulations. Objective: To analyze the influence of external hexagon implants in different inclinations (3 levels) on the microstrain distribution generated around three implants. Method: A geometric bone model was created through Rhinoceros CAD software (version 5.0 SR8, Mcneel North America, Seattle, WA, USA). Three implants (4.1 × 13 mm) were modeled and inserted inside the substrate at three different inclinations: 0º, 17º and 30º. Next, all groups received mini conical abutments, fixation screws and a simplified prosthesis. The final geometry was exported in STEP format to analysis software and all materials were considered homogeneous, isotropic and linearly elastic. An axial load (300N) was applied on the center of the prosthesis. An in vitro study was conducted with same conditions and groups for validating the tridimentional model. Result: Stress was concentrated on the external area of the implants, in contact with the cortical bone and external hexagon. For the bone simulator, the strain increased in the peri-implant region according to the increase in the implant's inclination. The difference between groups was significant (p = 0.000). The 30º group presented higher stress and strain concentration. Conclusion: The microstrain and stress increase around implants directly proportional to the increase of the installation angle.


Introdução: A inclinação dos implantes pode ser corrigida através de mini-pilares de diferentes angulações. Objetivo: Analisar a influência de implantes com hexágono externo em diferentes inclinações (3 níveis) na distribuição de microdeformações geradas em torno de três implantes. Método: Um modelo geométrico de osso foi criado através do software CAD Rhinoceros (versão 5.0 SR8, Mcneel North America, Seattle, WA, EUA). Três implantes (4,1 × 13 mm) foram modelados e inseridos no interior do substrato em três diferentes inclinações: 0º, 17º e 30º. Em seguida, todos os grupos receberam mini-pilares cônicos, parafusos de fixação e prótese simplificada. A geometria final foi exportada em formato STEP para software de análise e todos os materiais foram considerados homogêneos, isotrópicos e linearmente elásticos. Uma carga axial (300N) foi aplicada no centro da prótese. Um estudo in vitro foi conduzido com as mesmas condições e grupos para validar o modelo tridimensional. Resultado: A concentração de tensão ocorreu na área externa dos implantes, em contato com o osso cortical e o hexágono externo. Para o simulador ósseo, a deformação aumentou na região peri-implantar de acordo com o aumento da inclinação do implante. A diferença entre os grupos foi significativa (p = 0.000). O grupo de 30º apresentou maior concentração de tensão e deformação. Conclusão: O aumento da microdeformação e das tensões ao redor dos implantes aumenta diretamente proporcional ao aumento do ângulo de instalação.


Assuntos
Prótese Dentária Fixada por Implante , Análise de Elementos Finitos , Implantação Dentária
16.
Rev. odontol. UNESP (Online) ; 47(3): 149-154, maio-jun. 2018. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-961519

RESUMO

Introduction: A new dental implant-abutment design is available with the possibility of improving aesthetic with no compromise of mechanical strength, using perforated CAD/CAM ceramic blocks. Objective: This study evaluated the influence of crown and hybrid abutment ceramic materials combination on the stress distribution of external hexagon implant supported prosthesis. Method: Zirconia, lithium disilicate and hybrid ceramic were evaluated, totaling 9 combinations of crown and mesostructure materials. For finite element analysis, a monolithic crown cemented over a hybrid abutment (mesostructure + titanium base) was modeled and screwed onto an external hexagon implant. Models were then exported in STEP format to analysis software, and the materials were considered isotropic, linear, elastic and homogeneous. An oblique load (30°, 300N) was applied to the central fossa bottom and the system's fixation occurred on the bone's base. Result: For crown structure, flexible materials concentrate less stress than rigid ones. In analyzing the hybrid abutment, it presented higher stress values when it was made with zirconia combined with a hybrid ceramic crown. The stress distribution was similar regarding all combinations for the fixation screw and implant. Conclusion: For external hexagon implant, the higher elastic modulus of the ceramic crowns associated with lower elastic modulus of the hybrid abutment shows a better stress distribution on the set, suggesting a promising mechanical behavior.


Introdução: Um novo design de pilar para implantes dentários está disponível com a possibilidade de melhorar a estética sem comprometer a resistência mecânica, usando blocos cerâmicos perfurados para CAD/CAM. Objetivo: Este estudo avaliou a influência da combinação de diferentes materiais cerâmicos para coroa e para pilar híbrido na distribuição de tensões de prótese sobre implante hexágono externo. Método: Zircônia, dissilicato de lítio e cerâmica híbrida foram avaliados, totalizando 9 combinações de materiais para coroa e mesoestrutura. Para análise de elementos finitos, uma coroa monolítica cimentada sobre um pilar híbrido (mesoestrutura + base de titânio) foi modelada sobre um implante de hexágono externo. Os modelos foram exportados em formato STEP para o software de análise, e os materiais foram considerados isotrópicos, lineares, elásticos e homogêneos. Uma carga oblíqua (30°, 300N) foi aplicada no fundo da fossa central e a fixação do sistema ocorreu na base do osso. Resultado: Para a estrutura da coroa, os materiais flexíveis concentram menos tensão que os rígidos. Ao analisar o pilar híbrido, maiores valores de tensão foram observados quando feito com zircônia combinada com uma coroa de cerâmica híbrida. Em todas as combinações simuladas, a distribuição de tensões foi semelhante para o parafuso de fixação e o implante. Conclusão: Associar um material cerâmico com elevado módulo elástico para a coroa com um material de menor módulo elástico para o pilar híbrido resulta em menor concentração de tensão máxima principal, sugerindo um comportamento mecânico promissor para o sistema hexágono externo.


Assuntos
Implantes Dentários , Cerâmica , Desenho Assistido por Computador , Análise de Elementos Finitos , Coroas , Estética Dentária , Zircônio , Materiais Dentários
17.
Braz. j. oral sci ; 17: e18222, 2018. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-970620

RESUMO

Aim: The goal of this study was to clarify the stress distribution in a full arch prosthesis according to the implant number and height in order to guide the clinical choice during planning. Methods: A computational analysis was performed to analyze the stress distribution in implants and bone tissue according to implant number (3, 4 or 5) and height (5, 8, 11 mm). A model of a jaw with polyurethane properties to simulate bone tissue was created through the Rhinoceros software (version 5.0 SR8, McNeel North America, Seattle, WA, USA). The titanium bar was fixed to the implant through a retention screw. The final geometry was exported in STEP format to ANSYS (ANSYS 15.0, ANSYS Inc., Houston, USA) and all materials were considered homogeneous, isotropic and linearly elastic. To assess distribution of stress forces, an axial load (200 N) was applied on the cantilever. Results in Von-Mises stress and strain criteria's were obtained for implants and bone, respectively. Qualitative and quantitative evaluations were performed. Results: The implant number and height influenced the prosthesis biomechanics, with more von-Mises stress and bone strain concentration for combination of 3 implants with 5 mm. Conclusion: It was concluded that higer length and more quantity of implant supporting a full arch prosthesis promoted less stress concentration during the simulated load. Decreasing the number of implants in rehabilitation is more harmful than decreasing their length for the stress and strain distribution


Assuntos
Prostodontia , Resistência à Tração , Análise de Elementos Finitos , Interface Osso-Implante
18.
Braz. dent. sci ; 21(1): 88-95, 2018. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-881884

RESUMO

Objective: The aim of this study was to evaluate the effect of different surface clinical treatments on the roughness (Ra) of a lithium disilicate ceramic veneer. Material and Methods: Forty-eight lithium disilicate discs with ceramic veneer and glaze layer were manufactured and distributed into six groups (n=8) according to the surface treatment performed: G1, glaze layer (control group); G2, diamond bur 4138F; G3, diamond bur 4138F + 4138FF; G4, diamond bur 4138F + new glaze layer; G5, diamond bur 4138F + ceramic polishing kit; G6, diamond bur 4138F + rubber cup with diamond paste + felt with diamond paste. Surface Ra measurement (µm) was performed using a profilometer before and after surface treatments, and one specimen from each group was subjected to Scanning Electron Microscopy (SEM) after treatment. Two-way ANOVA and Tukey's test (5%) were used for data analysis. Results: Group 2 (3,00 ± 0,61)b showed higher values of Ra, followed by Group 3 (1,93 ± 0,45)c , Group 6 (1,56 ± 0,22) ac, Group 5 (1,14 ± 0,68)a and Group 4 (0,90 ± 0,26)a . G4, G5 and G6 were not different between each other and control group (1,11 ± 0,21)a . SEM imaging revealed surface smoothness in G1, G4 and G5, and presence of irregularities in G2, G3 and G6. Conclusion: it is possible to conclude that different surface clinical treatments influences the roughness of a lithium disilicate ceramic veneer (AU)


Objetivo: o objetivo deste estudo foi avaliar o efeito de diferentes tratamentos clínicos de superfície na rugosidade (Ra) de uma cerâmica de cobertura de dissilicato de lítio. Material e Métodos: foram fabricados e distribuídos quarenta e oito discos de dissilicato de lítio com cerâmica de revestimento e vitrificação em seis grupos (n = 8) de acordo com o tratamento de superfície realizado: G1, camada vitrificada (control group); G2, ponta diamantada 4138F; G3, ponta diamantada 4138F + 4138FF; G4, ponta diamantada 4138F + nova camada vitrificada; G5, ponta diamantada 4138F + kit de polimento cerâmico; G6, ponta diamantada 4138F + taça de borracha com pasta diamantada + feltro com pasta diamantada. A análise da superfície Ra (µm) foi realizada usando-se um perfilômetro antes e depois dos tratamentos de superfície, e uma amostra de cada grupo foi à Microscopia Eletrônica de Varredura (MEV) após o tratamento. Two-way ANOVA e o teste de Tukey (5%) foram utilizados para análise de dados. Resultados: O Grupo 2 (3,00 ± 0,61)b apresentou valores mais altos de Ra, seguido do Grupo 3 (1,93 ± 0,45) c , Grupo 6 (1,56 ± 0,22)ac, Grupo 5 (1,14 ± 0,68)a e Grupo 4 (0,90 ± 0,26)a . G4, G5 e G6 não eram diferentes entre si e entre grupo de controle (1,11 ± 0,21)a . A imagem de MEV revelou suavidade da superfície em G1, G4 e G5, e presença de irregularidades em G2, G3 e G6. Conclusão: é possível concluir que diferentes tratamentos clínicos de superfície influenciam a rugosidade de uma cerâmica de revestimento de dissilicato de lítio.(AU)


Assuntos
Cerâmica , Polimento Dentário , Porcelana Dentária
19.
Braz. dent. sci ; 21(1): 96-103, 2018. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-881930

RESUMO

Objective: This study evaluated the effects of the incorporation of silver nanoparticles (AgNPs) obtained from Fusarium oxysporum on heat-activated acrylic resin (HAAR) and their influence on resin's surface roughness, hardness, color alteration and antimicrobial capacity against Candida albicans. Material and Methods: For this, 50 discs of HAAR (2x5 mm) were produced and divided into three groups, Control: HAAR; Ag1: HAAR plus 0.539 mg of AgNPs; and Ag2: HAAR plus 1.1 mg of AgNPs. Knopp hardness (HK), surface roughness (Ra and Rz) and color alteration according to the CIE Lab were measured. Specimens were then evaluated in vitro with regard to C. albicans biofilm formation through formed colony count (CFU/mL). Scanning Electron Microscopy (SEM) and Atomic force microscopy (AFM) analyses were performed. Results: The addition of AgNPs of both concentrations changed Ra, Rz and HK significantly. There was statistically significant difference for L (p=0.00); a*(p=0.00) and b*(p=0.00) parameters. There were no differences between Ag1 and Ag2 biofilm formation, but the comparison of both with the control group presented a significant reduction (p=0.0091) on biofilm formation. SEM and AFM images showed no signs of NPs clustering. Conclusion: It can be concluded tha AgNPs incorporation in HAAR was effective in reducing C. albicans activity, with a slight change in color and hardness of the material, being effective therefore, in regions such as the dental prostheses palate, which have lesser aesthetic appeal. (AU)


Objetivo: Este estudo avaliou os efeitos da incorporação de nanopartículas de prata (AgNPs) obtidas a partir de Fusarium oxysporum em resina acrílica ativada termicamente (RAAT) e sua influência na rugosidade, dureza, cor e capacidade antimicrobiana contra Candida albicans. Material e Métodos: Para isso, 50 discos de RAAT (2x5 mm) foram produzidos e divididos em três grupos, Controle: RAAT; Ag1: RAAT com 0,539 mg de AgNPs; e Ag2: RAAT com 1,1 mg de AgNPs. Foram medidas a dureza Knopp (DK), a rugosidade superficial (Ra e Rz) e a alteração da cor de acordo com o sistema CIE Lab. As amostras foram então avaliadas in vitro em relação à formação de biofilme de C. albicans através da contagem de unidades formadoras de colônia (UFC / mL). Foram realizadas análises de Microscopia Eletrônica de Varredura (MEV) e Microscopia de Força Atômica (AFM). Resultados: A adição de AgNPs de ambas as concentrações alterou significativamente Ra. Rz e DK. Houve diferença estatisticamente significativa para os parâmetros L (p = 0,00); a * (p = 0,00) e b * (p = 0,00). Não houve diferenças entre a formação de biofilme Ag1 e Ag2, mas a comparação entre ambos com o grupo controle apresentou redução significativa (p = 0,0091) na formação de biofilmes. As imagens de MEV e AFM não mostraram sinais de agrupamento de NPs. Conclusão: Pode-se concluir que a incorporação de AgNP no RAAT foi eficaz na redução da atividade de C. albicans, com uma discreta alteração na cor e dureza do material, sendo efetiva, portanto, em regiões linguais de próteses dentárias, que possuem menor apelo estético. (AU)


Assuntos
Resinas Acrílicas , Anti-Infecciosos , Prata
20.
Braz. dent. sci ; 21(4): 432-436, 2018. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-966180

RESUMO

Objective: The aim of this study was to evaluate the influence of mixing method and the empiric water/powder ratio on the dimensional change of two types of dental stones (type III and type IV) at different setting times: baseline, loss of brightness, initial and final setting (1/4 and 1pound Gilmore´s needle, respectively) and, after 48 hours at 37°C. Material and Methods: Five mixing methods were used: Gc ­ manufacturer´s recommendation, G1 ­ weighed powder/ empiric water volume and powder on water, G2 - weighed powder/ empiric water volume and water on powder, G3 ­ empiric powder volume, graduated water and powder on water, G4 - empiric powder volume, graduated water and water on powder. The linear expansion was measured according to ISO 6873. The expansion values (x10-2mm) were analyzed by Two-way ANOVA and Tukey HSD test (α=0.05). Results: For type III, the results showed significance for both factors and for interaction; for type IV, only the time were significant ( p<0.05). Limited by methodology, it could be concluded that both dental stones expanded more than the recommended by ISO. Conclusion: The expansion of type III was dependent on the mixing method, and once correct consistency is reached with type IV, there is no influence of mixing method on dimensional stability. (AU)


Objetivo: O objetivo deste estudo foi avaliar a influência do método de mistura e da relação empírica de água/pó na alteração dimensional de dois tipos de gessos odontológicos (tipo III e tipo IV) em diferentes tempos de trabalho: baseline, perda de brilho, inicial e final (agulha de Gilmore de 1/4 e 1 libra, respectivamente) e, após 48 horas a 37 ° C. Material e Métodos: Cinco métodos de mistura foram utilizados: Gc - recomendação do fabricante, G1 - pó pesado / volume empírico de água e pó na água, G2 - pó pesado / volume empírico de água e água no pó, G3 - volume empírico de pó, água graduada e pó na água, G4 - volume de pó empírico, água graduada e água no pó. A expansão linear foi medida de acordo com a norma ISO 6873 (1998). Os valores de expansão (x10-2mm) foram analisados pelo teste ANOVA dois fatores e teste de Tukey HSD (α = 0,05). Resultados: Para o tipo III, os resultados mostraram significância para ambos os fatores e para interação; para o tipo IV, apenas o tempo foi significativo (p < 0,05). Limitado pela metodologia, pode-se concluir que ambos os gessos odontológicos expandiram mais do que o recomendado pela ISO. Conclusão: A expansão do tipo III foi dependente do método de mistura e, uma vez atingida a consistência correta com o tipo IV, não há influência do método de mistura na estabilidade dimensional. (AU)


Assuntos
Sulfato de Cálcio , Expansão de Tecido , Técnica de Expansão Palatina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA